Sysmex South Africa
Menu

XN-450

With the XN-450 you can run single samples safely in closed mode. The instrument offers open mode too and comes with a fully integrated IPU, including an LCD colour touchscreen that makes it easy to operate. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future, it can be upgraded by adding new clinical and productivity values, or by opting for further professional services and connecting to our Extended IPU as your demands change.

Features

Specialist solutions for niche diagnostics

The XN-L Series delivers specialist solutions for labs that need to offer niche diagnostics. Dedicated functionalities support the following medical specialties:

  • Paediatrics. Low aspiration volume of 25 μL plus the availability of an IG count and HFLC* information with every DIFF analysis.
  • Dialysis centres. The RET-He parameter (with RET) and CAPD measurement (with XN-BF) for monitoring patients.
  • Neurology wards. Dedicated analysis for various body fluids (with XN-BF) – fast and available 24/7.
  • Oncology. Precise and accurate measurement of leucocytopenic samples (with L-WBC) helps, for example, to obtain reliable neutrophil counts during chemotherapy.

*research parameter

Technical Specifications
Dimensions / weights
W x H x D [mm / kg
XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput up to 60 samples/h in WB mode
up to 70 samples/h in WB mode with the optional Speed-up licence
Aspiration volume 25 µL in WB mode,
70 µL in PD and BF mode
Analysis parameters Whole Blood
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%

With RET (optional)
RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O

Body Fluids with XN-BF (optional)
WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles  WBC DIFF/RET: Fluorescence Flow Cytometry
WBC: Flow Cytometry
RBC/PLT: DC Impedance method with hydrodynamic
focussing
HGB: Cyanide-free SLS method
Data storage capacities Results: 100,000 samples
Patient information: 10,000 records
Calibration history: 20 times/ module
QC files: 99 files including XbarM
User maintenance     Daily shutdown
Weekly cleaning sequence with Cellclean or Cellclean Auto
Contacts
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex South Africa (Pty) Ltd

Fernridge Office Park, Block 1,

Randburg 2194

+27 (11) 329 94 80

Documents

Product documents

Safety data sheets

Regulatory Documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

Copyright © Sysmex Europe SE. All rights reserved.